Number of points a final circuit should supply - October's Question of the Month

21.10.2009
ETCI
 

This Question of the Month, concerning final circuit supply, is answered by ETCI:

Question: How many points should a final circuit in a domestic premises supply?

Answer: This depends whether the circuits are radial or ring final circuits.

For a radial circuit the maximum number of points recommended is 10 per circuit. This applies to either lighting circuits or socket outlets etc. In the case of socket outlets a twin socket outlet would count as one point. For final socket circuits it is recommended that a radial circuit should not serve more than two rooms.

For ring final circuits the number of points is unlimited within a floor area of 100 sq. meters.


 Back

 Related contacts
Electro-Technical Council of Ireland Ltd,
ETCI Offices, Unit H12,
Centrepoint Business Park,
Oak Road, Dublin 12, Ireland
Telephone: 01-4290088
Fax: 01-4290090

 For latest electrical industry news, register for Voltimum's free newsletter.
Enter your email address here:
OK

Source: Voltimum / ETCI

Related information

Related contacts

More News...

Get involved with smart grids
ETCI warning on cable colours
Wiring in attics - June's Question of the Month
Electrical equipment in airing cupboards - May's Question of the Month
New National Rules notices from TC2
Heights of wall switches - March's Question of the Month
Colour cores of fixed cables - February's Question of the Month
New 4th Edition guidelines
Installing a shower in an existing installation - January's Question of the Month