Leica NA730 - Leica Geosystems Leica NA730 - Leica Geosystems Leica NA730 - Leica Geosystems

[...] ground, a fall into water, vibration from heavy machinery – with a Leica NA700 level you[...] Single measurement – Target distance 30m 0.8 mm Compensator Setting accuracy < 0.3" Working range ? 15' Environmental Impact standard ISO 9022 - 33 - 5 Resistance [...]

Introducing the NEW Leica Lino L2+ Cross line laser Introducing the NEW Leica Lino L2+ Cross line laser Introducing the NEW Leica Lino L2+ Cross line laser

/ laser class II Batteries type AA / 4 x 1.5 V Protection class IP 54 splash water and dustproof

Fluke TiR32 - Fluke Fluke TiR32 - Fluke Fluke TiR32 - Fluke

focus distance 15 cm Thermal sensitivity (NETD) ≤0.05 °C at 30 °C (50 mK) Minimum span (Auto[...] - angle infrared lens type Yes Visual [...]

Fluke Ti32 - Fluke Fluke Ti32 - Fluke Fluke Ti32 - Fluke

focus distance 15 cm Thermal sensitivity (NETD) ≤0.05 °C at 30 °C (50 mK) Minimum span (Auto[...] - angle infrared lens type Yes Visual [...]

When it comes to measuring, Leica Geosystems have got it taped!!! When it comes to measuring, Leica Geosystems have got it taped!!! When it comes to measuring, Leica Geosystems have got it taped!!!

needs. Some manufacturers lead and others follow..when we invented the laser distance meter[...] accuracies to ? 1.0mm and can measure up to a distance of 200 metres. The DISTO? sends a laser dot 200[...], [...]

MV Reducer Splices - Water Blocked MV Reducer Splices  -  <b>Water</b> Blocked MV Reducer Splices  -  <b>Water</b> Blocked

These MV splices allow copper conductors of differing cross sectional areas to be joined in a neat waterblocked design.

My Straight Splices - Water Blocked My Straight Splices  -  <b>Water</b> Blocked My Straight Splices  -  <b>Water</b> Blocked

The splices incorporate a solid central waterblock to provide a moisture seal when jointing MIND paper insulated to polymeric cables.

Fluke TiRx - Fluke Fluke TiRx - Fluke Fluke TiRx - Fluke

focus distance 15 cm Thermal sensitivity (NETD) ≤0.1 °C at 30 °C (100 mK) Minimum span (Auto[...] operating time 3 to 4 hours continuous operation Water and dust resistant: IP54 Size (HxWxD): 267 x 127 x

Fluke Ti9 - Fluke Fluke Ti9 - Fluke Fluke Ti9 - Fluke

focus distance 15 cm Thermal sensitivity (NETD) ≤0.2 °C at 30 °C (200 mK) Minimum span (Auto[...] time 3 to 4 hours continuous operation Battery life: 3 to 4 hours continuous operation Water and dust

control desk control desk control desk

What are the components required for the control desk of water treatment plant