NSX250H 3P 70kA Frame
NSX250H 3P 70kA Frame
- SKU
range of product: NSX100...250,NSX100...250
device short name: Compact NSX250H,Compact NSX250H
circuit breaker name: Compact NSX250H,Compact NSX250H
poles description: 3P,3P
[In] rated current: 250 A ( 40 °C ),250 A ( 40 °C )
[Ui] rated insulation voltage: 800 V AC 50/60 Hz conforming to IEC 60947-2,800 V AC 50/60 Hz conforming to IEC 60947-2
[Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947-2,8 kV conforming to IEC 60947-2
[Ue] rated operational voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2,690 V AC 50/60 Hz conforming to IEC 60947-2
breaking capacity code: H,H
breaking capacity: Icu 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2,Icu 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2,Icu 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2,Icu 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2,Icu 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2,Icu 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2,Icu 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2,Icu 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2,35 kA at 600 V AC 50/60 Hz conforming to NEMA AB1,35 kA at 600 V AC 50/60 Hz conforming to NEMA AB1,65 kA at 480 V AC 50/60 Hz conforming to NEMA AB1,65 kA at 480 V AC 50/60 Hz conforming to NEMA AB1,15 kA at 600 V AC 50/60 Hz conforming to UL 508,15 kA at 600 V AC 50/60 Hz conforming to UL 508,100 kA at 240 V AC 50/60 Hz conforming to NEMA AB1,100 kA at 240 V AC 50/60 Hz conforming to NEMA AB1,65 kA at 480 V AC 50/60 Hz conforming to UL 508,65 kA at 480 V AC 50/60 Hz conforming to UL 508,85 kA at 240 V AC 50/60 Hz conforming to UL 508,85 kA at 240 V AC 50/60 Hz conforming to UL 508,Icu 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2,Icu 10 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2,Icu 100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2,Icu 100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2
[Ics] rated service breaking capacity: Ics 10 kA 660/690 V AC 50/60 Hz conforming to IEC 60947-2,Ics 10 kA 660/690 V AC 50/60 Hz conforming to IEC 60947-2,Ics 100 kA 220/240 V AC 50/60 Hz conforming to IEC 60947-2,Ics 100 kA 220/240 V AC 50/60 Hz conforming to IEC 60947-2,Ics 35 kA 525 V AC 50/60 Hz conforming to IEC 60947-2,Ics 35 kA 525 V AC 50/60 Hz conforming to IEC 60947-2,Ics 70 kA 380/415 V AC 50/60 Hz conforming to IEC 60947-2,Ics 70 kA 380/415 V AC 50/60 Hz conforming to IEC 60947-2,Ics 65 kA 440 V AC 50/60 Hz conforming to IEC 60947-2,Ics 65 kA 440 V AC 50/60 Hz conforming to IEC 60947-2,Ics 50 kA 500 V AC 50/60 Hz conforming to IEC 60947-2,Ics 50 kA 500 V AC 50/60 Hz conforming to IEC 60947-2
suitability for isolation: yes conforming to EN 60947-2,yes conforming to EN 60947-2,yes conforming to IEC 60947-2,yes conforming to IEC 60947-2
pollution degree: 3 conforming to IEC 60947-1,3 conforming to IEC 60947-1