Skip to content

3P NSX400H WITHOUT TRIP UNIT

Link copied
SKU
range of product: NSX400...630,NSX400...630 device short name: Compact NSX400H,Compact NSX400H circuit breaker name: Compact NSX400H,Compact NSX400H poles description: 3P,3P network type: AC,AC network frequency: 50/60 Hz,50/60 Hz [In] rated current: 400 A ( 40 °C ),400 A ( 40 °C ) [Ui] rated insulation voltage: 800 V AC 50/60 Hz conforming to IEC 60947-2,800 V AC 50/60 Hz conforming to IEC 60947-2 [Uimp] rated impulse withstand voltage: 8 kV conforming to IEC 60947-2,8 kV conforming to IEC 60947-2 [Ue] rated operational voltage: 690 V AC 50/60 Hz conforming to IEC 60947-2,690 V AC 50/60 Hz conforming to IEC 60947-2 breaking capacity code: H,H breaking capacity: 20 kA at 600 V AC 50/60 Hz conforming to UL 508,20 kA at 600 V AC 50/60 Hz conforming to UL 508,35 kA at 600 V AC 50/60 Hz conforming to NEMA AB1,35 kA at 600 V AC 50/60 Hz conforming to NEMA AB1,65 kA at 480 V AC 50/60 Hz conforming to NEMA AB1,65 kA at 480 V AC 50/60 Hz conforming to NEMA AB1,100 kA at 240 V AC 50/60 Hz conforming to NEMA AB1,100 kA at 240 V AC 50/60 Hz conforming to NEMA AB1,Icu 20 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2,Icu 20 kA at 660/690 V AC 50/60 Hz conforming to IEC 60947-2,Icu 100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2,Icu 100 kA at 220/240 V AC 50/60 Hz conforming to IEC 60947-2,65 kA at 480 V AC 50/60 Hz conforming to UL 508,65 kA at 480 V AC 50/60 Hz conforming to UL 508,85 kA at 240 V AC 50/60 Hz conforming to UL 508,85 kA at 240 V AC 50/60 Hz conforming to UL 508,Icu 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2,Icu 50 kA at 500 V AC 50/60 Hz conforming to IEC 60947-2,Icu 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2,Icu 65 kA at 440 V AC 50/60 Hz conforming to IEC 60947-2,Icu 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2,Icu 70 kA at 380/415 V AC 50/60 Hz conforming to IEC 60947-2,Icu 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2,Icu 35 kA at 525 V AC 50/60 Hz conforming to IEC 60947-2 [Ics] rated service breaking capacity: Ics 11 kA 525 V AC 50/60 Hz conforming to IEC 60947-2,Ics 11 kA 525 V AC 50/60 Hz conforming to IEC 60947-2,Ics 10 kA 660/690 V AC 50/60 Hz conforming to IEC 60947-2,Ics 10 kA 660/690 V AC 50/60 Hz conforming to IEC 60947-2,Ics 100 kA 220/240 V AC 50/60 Hz conforming to IEC 60947-2,Ics 100 kA 220/240 V AC 50/60 Hz conforming to IEC 60947-2,Ics 50 kA 500 V AC 50/60 Hz conforming to IEC 60947-2,Ics 50 kA 500 V AC 50/60 Hz conforming to IEC 60947-2,Ics 65 kA 440 V AC 50/60 Hz conforming to IEC 60947-2,Ics 65 kA 440 V AC 50/60 Hz conforming to IEC 60947-2,Ics 70 kA 380/415 V AC 50/60 Hz conforming to IEC 60947-2,Ics 70 kA 380/415 V AC 50/60 Hz conforming to IEC 60947-2 suitability for isolation: yes conforming to EN 60947-2,yes conforming to EN 60947-2,yes conforming to IEC 60947-2,yes conforming to IEC 60947-2 utilisation category: category A,category A pollution degree: 3 conforming to IEC 60947-1,3 conforming to IEC 60947-1